T05:14:10.794Z cpu35:65677)NetLB: 2233: Driver claims supporting 7 TX queues, and 7 queues are accepted.

T05:14:10.794Z cpu35:65677)NetLB: 2237: Driver claims supporting 7 RX queues, and 7 queues are accepted. T05:13:40.794Z cpu26:80280)WARNING: netschedHClk: NetSchedHClkWatchdogSysWorld:4695: vmnic0: failed to push the coalescing settings cranking upinflight window to infinite: Not supported T05:13:40.794Z cpu26:80280)netschedHClk: NetSchedHClkWatchdogSysWorld:4552: vmnic0: link up event received, device running at 10000 Mbps so setting queue depth to 86460 bytes with expected 1310 bytes/us ESXi 6.5 ( Net.TeamPolicyUpdelay In-Value 30000ms) In ESXi 6.7, even if you changed the setting, you had to have a delay (30000 ms) at the time you set, but it did not work.ġ. In ESXi 6.5, Net.TeamPolicyUpdelay works as set. (Configuration that does not cause ping loss when having linkage with BCF) In accordance with the recommendation, the Net.TeamPolicyUpdelay setting was changed from the default value of 100ms to 30000ms.Īfter redundancy link is restored, it should have 30000ms of delay but is applied as 100ms, causing ping loss. In a configuration that works with Big Switch Cloud Fabric, The application environment is like this. Net.TeamPolicyUpDelay Setting Does Not Working For ESXi 6.7